The two pond system is fed by a stream with flow rate 1.0 MGD (million gallons per day) and BOD (nonconservative pollutant) concentration of 20 mg/L. The rate of decay of BOD is 0.3/day. The volume of the first pond is 5 million gallons and the second is 3 million. Assuming complete mixing within the pond, find the BOD concentration leaving each pond.